I. Power System Faults
1. Difficulty Starting
Common causes: Clogged fuel filter, abnormal carburetor operation, improper ignition coil/spark plug clearance, governor parameter deviation, or incompatible fuel grade, or water in the fuel tank.
2. Insufficient Power
Common causes: Excessive valve clearance, worn valve base, or excessive wear of the cylinder, piston, or piston rings, leading to a significant decrease in compression efficiency.
II. Vibration System Faults
1. Motor Runs Normally but No Vibration
Common causes: Displacement or breakage of the eccentric block, slippage or detachment of the drive belt, jamming of the vibration shaft, or loose fastening bolts on the eccentric wheel, preventing power transmission to the vibration mechanism.
2. Weak/Uneven Vibration
Common causes: Aging and failure of the damping pads, uneven wear of the eccentric block, loose connection of the compactor plate, or insufficient output pressure of the hydraulically driven vibration motor.
III. Hydraulic System Failures (Hydraulic Models)
1. Leakage
Common causes: Aging or damaged seals, loose pipe joints, ruptured oil pipes, leading to hydraulic oil leakage and rapid pressure loss in the system.
2. Abnormal Oil Temperature Rise and Loud Noise
Common causes: Insufficient hydraulic oil level, impurities clogging the oil passages, air entering the system causing cavitation, or poor cooling system performance leading to inadequate heat dissipation.
3. Insufficient Pressure and Slow Operation
Common causes: Wear and internal leakage in the hydraulic pump, malfunctioning relief valve, contaminated oil causing valve core jamming, preventing the system from establishing rated working pressure.
IV. Electrical System Failures
1. Motor Does Not Start After Power On
Common causes: Phase loss in power supply, poor contact in the switch, loose or burnt wires in the motor junction box, or seized motor bearings, or overload triggering protection.
2. Sudden Shutdown During Operation
Common causes: Damaged or short-circuited cables, triggered thermal protection components, or loosened wiring connections due to vibration causing power loss.
V. Other Common Faults
Abnormal noises during operation are mostly caused by loose parts, insufficient lubrication, or excessive wear of friction pairs. The machine must be stopped immediately for inspection and tightening. Long-term improper overloading will also accelerate the aging of machine components, significantly increasing the probability of failure.